Репозитарій КНУ
Увійти(current)
  1. Головна
  2. Наукова періодика | Scientific periodicals
  3. French-Ukrainian Journal of Chemistry
  4. 2015
  5. French-Ukrainian Journal of Chemistry. Vol. 3 No. 2
  6. Gas Chromatographic determination of parabens after derivatization and dispersive microextraction

Gas Chromatographic determination of parabens after derivatization and dispersive microextraction

Тип публікації :
Стаття
Дата випуску :
2015
Автор(и) :
Levchyk, Valentyna M.
Zui, Marina F.
Мова основного тексту :
Англійська
eKNUTSHIR URL :
https://ir.library.knu.ua/handle/15071834/25598
DOI :
10.17721/fujcV3I2P72-79
Журнал :
French-Ukrainian Journal of Chemistry  
Том :
3
Випуск :
2
ISSN :
2312-3222
Початкова сторінка :
72
Кінцева сторінка :
79
Цитування :
[APA 7] Levchyk, V. M., & Zui, M. F. (2015). Gas Chromatographic determination of parabens after derivatization and dispersive microextraction. French-Ukrainian Journal of Chemistry, 3(2), 72–79. https://doi.org/10.17721/fujcV3I2P72-79
[ДСТУ] Levchyk V. M., Zui M. F. Gas Chromatographic determination of parabens after derivatization and dispersive microextraction. French-Ukrainian Journal of Chemistry. 2015. Vol. 3, no. 2. P. 72—79. DOI: 10.17721/fujcV3I2P72-79 (date of access: 25.07.2026).
Abstract. In this study a dispersive liquid–liquid microextraction  method combines with an in situ derivatization. The proposed method is used for the extraction and pre-concentration of some preservatives including methyl paraben, ethyl paraben, propyl paraben and butyl paraben from different water matrices. The extracted compounds are monitored by gas chromatography-flame ionization detector.  Parabens are derivatizated by propionic anhydride. The effects of the extraction solvent type, extraction and acylation time, derivative agent volume, temperature, pH and the ionic strength of the solution on the extraction efficiency were investigated. 50 mkl chloroform and 500 mkl acetonitrile is a mixture of suitable extraction and dispersive solvents. The mixture is centrifuged for 3min at 4000 rpm. 20 mkl propionic anhydride is used for derivatization parabens in the concentration range of 0.05 - 1 mg  within 2 - 3 minutes. The optimum pH range is 8 - 9. The relative standard deviations (RSDs) of parabens were in the range of 2.0–10.0% (n = 3). The method was applied to the analysis of the four parabens in water. For the analysis of the spiked samples, a recovery above 100 % were obtained.
Ключові слова :
paraben DLLME derivatization
Файл(и) :
Вантажиться...
Ескіз
Завантажити
Формат :

Adobe PDF

Розмір :

389.13 KB

Контрольна сума :

(MD5):b3dc176210556d951b875567e02fdacb

Creative Commons Attribution 4.0 International
Якщо не вказано інше, ця робота розповсюджується на умовах ліцензії Creative Commons Attribution 4.0 International
Контакти
  • ir.library@knu.ua
  • (044) 239-33-30
  • м. Київ, вул. Володимирська, 58, к. 42

Побудовано за допомогою Програмне забезпечення DSpace-CRIS - Розширення підтримується та оптимізується 4Наука

  • Доступність
  • Політика приватності
  • Угода користувача
  • Надіслати відгук