Otto, G. K.G. K.Otto2026-06-302026-06-302019Otto, G. K. (2019). Interferometry feedback in the laser resonator. Parametric model.. Bulletin of Taras Shevchenko National University of Kyiv. Physics and Mathematics(3), 62–69. https://doi.org/10.17721/1812-5409.2019/3.910.17721/1812-5409.2019/3.9https://ir.library.knu.ua/handle/15071834/26285The article is devoted to an alternative view on the explanation of the mechanism of action of devices based on laser feedback interferometry (LFI-model), which is caused by contradictions between the theory of existing models and practical results. A view other than the Lang-Kobayashi model (LK model) and the parametric LFI model (P model) are proposed. Due to the theory, which is based on the parametric properties of the LFI-model, the level of advantage of LFI technology over traditional technologies is quantitatively substantiated. The article gives an example of calculating the useful signal power. It is calculated that at a distance of 500 meters, the signal according to the P-model is 34 dB higher than the signal calculated by traditional models. Thus, from the traditional models follows the inverse square dependence of the signal-to-noise ratio (S / N ratio, hereinafter - SNR) on the distance to the target l_t, viz.: SNR ~ l_t^{-2}. In practice, the SNR is much higher. Within the P-model, another dependence of SNR on l_t, is theoretically proved and experimentally confirmed, viz.: SNR ~ (l_t * ln l_t^2)^{-1/2}. Traditional models do not consider the presence of a useful signal in the pump current, while, in fact, its power is more than 10 times greater than the radiation power in the resonator. The P-model eliminates contradictions between theoretical models and practical results.Key words: interferometry, LFI model, pump current.Pages of the article in the issue: 62 - 69Language of the article: UkrainianThe article is devoted to an alternative view on the explanation of the mechanism of action of devices based on laser feedback interferometry (LFI-model), which is caused by contradictions between the theory of existing models and practical results. A view other than the Lang-Kobayashi model (LK model) and the parametric LFI model (P model) are proposed. Due to the theory, which is based on the parametric properties of the LFI-model, the level of advantage of LFI technology over traditional technologies is quantitatively substantiated. The article gives an example of calculating the useful signal power. It is calculated that at a distance of 500 meters, the signal according to the P-model is 34 dB higher than the signal calculated by traditional models. Thus, from the traditional models follows the inverse square dependence of the signal-to-noise ratio (S / N ratio, hereinafter - SNR) on the distance to the target l_t, viz.: SNR ~ l_t^{-2}. In practice, the SNR is much higher. Within the P-model, another dependence of SNR on l_t, is theoretically proved and experimentally confirmed, viz.: SNR ~ (l_t * ln l_t^2)^{-1/2}. Traditional models do not consider the presence of a useful signal in the pump current, while, in fact, its power is more than 10 times greater than the radiation power in the resonator. The P-model eliminates contradictions between theoretical models and practical results.Key words: interferometry, LFI model, pump current.Pages of the article in the issue: 62 - 69Language of the article: UkrainianenInterferometry feedback in the laser resonator. Parametric model.Interferometry feedback in the laser resonator. Parametric model.Стаття